Search results for "Middle ear surgery"

showing 3 items of 3 documents

Bioactive Glass-Ceramics in Middle Ear Surgery An 8-Year Review

1988

An 8-year follow-up of Ceravital middle ear prostheses showed there was extremely good tolerance in the middle ear space. Incompatibility phenomena were not observed, and inflammatory reactions were neither caused nor supported by the implants. The tympanoplasties were always performed without interposition of cartilage between the tympanic membrane or the tympanic membrane graft and the disk-shaped portion of the implant, and extrusions were never observed. Long-lasting inflammatory processes appeared to destroy implants the same way they destroy ossicles. Transient inflammatory periods (such as episodes of purulent otitis media, which occurred soon after the prostheses were implanted) did…

CeramicsTympanic MembraneChemical PhenomenaEar MiddleDentistryBiocompatible MaterialsProsthesis DesignEpitheliumGeneral Biochemistry Genetics and Molecular Biologylaw.inventionHistory and Philosophy of SciencelawmedicineHumansOssiclesChemistry Physicalbusiness.industryGeneral NeuroscienceCartilageOssicular Prosthesismedicine.anatomical_structureHearing resultsMiddle ear surgeryBioactive glassMiddle earImplantPurulent Otitis MediabusinessEar CanalAnnals of the New York Academy of Sciences
researchProduct

Handheld laser-fiber vibrometry probe for assessing auditory ossicles displacement

2021

Significance: Measurements of auditory ossicles displacement are commonly carried out by means of laser-Doppler vibrometry (LDV), which is considered to be a gold standard. The limitation of the LDV method, especially for in vivo measurements, is the necessity to expose an object in a straight line to a laser beam operating from a distance. An alternative to this approach is the use of a handheld laser-fiber vibrometry probe (HLFVP) with a curved tip. Aim: We evaluate the feasibility of an HLFVP with a curved tip for measuring sound-induced displacement of the auditory ossicles. Approach: A handheld vibrometer probe guiding the laser beam with a fiber-optic cable was used for displacement m…

BiomaterialsPaperSensinglaser-fiber vibrometerhandheld probeBiomedical Engineeringlaser-Doppler vibrometermiddle ear surgeryAtomic and Molecular Physics and Opticsmiddle ear mechanicsElectronic Optical and Magnetic MaterialsJournal of Biomedical Optics
researchProduct

The prognostic value of subjective nasal symptoms and SNOT-22 score in middle ear surgery

2022

Background: The relationship between nasal functions and middle ear surgery is still under debate. Nasal obstruction is considered as a negative prognostic factor in middle ear surgery. This is based on the theory that it may cause Eustachian tube dysfunction (ETD) by leading to reduced ventilation of the middle ear, as found in several patients with nasal septal deviation, chronic rhinitis and nasal polyps. Objectives: To assess how the subjective feeling of nasal function, evaluated by a preoperative questionnaire, may be predictive of surgical outcome and/or risk of failure in middle ear surgery. Methods: We prospectively evaluated data of patients undergoing middle ear surgery for chron…

Prognostic factorOtorhinolaryngologyEustachian TubeSNOT-22Tympanic membraneChronic DiseaseEar MiddleHumansSino-Nasal Outcome TestEar DiseasesPrognosisMiddle ear surgeryAmerican Journal of Otolaryngology
researchProduct